In many places from chemistry laboratories to industrial facilities, to be able to guarantee the security of life and property towards a possible hearth hazard, extinguishing systems are used in addition to detection and alarm techniques. It is also extraordinarily necessary that the extinguishing techniques installed could be triggered by the fireplace extinguishing control panel, in order to eliminate a potential fire with early intervention.
In order to satisfy these needs, and with 35 years of sectoral information and expertise, Mavili Elektronik presents:
Maxlogic Conventional Fire Extinguishing Control Panel operating based on the cross-zone detection precept;
Maxlogic Extinguishing Status Indicator Unit, which allows the distant efficiency of the indications and controls on the Control Panel;
Maxlogic Extinguishing Output Expansion Panel;
Maxlogic Extinguishant Manual Release Button, which permits the extinguishing course of to be started manually and remotely; and
to guarantee that the extinguishing process could be paused, Maxlogic has produced the Extinguishant Emergency Stop Button.
All these units are produced using surface-mount technology and are aimed at making the automation of the extinguishing system and fireplace and gas detection system perfect.
Image copyright: Mavili
Mavili Elektronik develops its merchandise by at all times contemplating the wants of the installation. In instances that require the combination of the extinguishing system with the intelligent addressable hearth detection system, it supplies options through the monitoring modules that even have a ‘supervised’ possibility.
Supervised monitoring modules play an necessary role in controlling the continuity of the cable connection between the loop and the extinguishing system. Failure to detect a possible open or short circuit in the wiring between the contact monitoring modules and the peripheral methods may cause disruption of the triggering, with potentially important consequences. For this cause, when choosing monitoring modules, it should be taken into consideration that they have supervised features.
Image copyright: Mavili
Since Maxlogic clever addressable fireplace detection and alarm management panels are constantly communicating with ‘supervise’ contact monitoring modules related to cable loops and compliant with EN 54-17 and EN 54-18 requirements, it makes it simpler to observe situations such as open circuits and quick circuits that will occur within the system. Many tasks could be carried out in the fireplace extinguishing installation, such as the management and monitoring of all valves that can interrupt the circulate of water, water move alarm switches, pressure change, and electrical or diesel fireplace pumps.
By including pressure gauge weksler ราคา monitoring modules to 2 separate relay outputs located above the Maxlogic Conventional Fire Extinguishing Control Panel, one of the modules can be utilized to regulate errors and the other to manage the fireplace scenario, monitoring and control of the extinguishing system via an intelligent addressable hearth detection and alarm system could be performed successfully.
For extra info, go to www.mavili.com.tr/en
Share

Leave a Reply